MarcoV6T
Hi, I try to use one of the auxiliary output functions as a feedback source (or even better as an axis source), so we do not need to specify a physical output for it, and use another analog input to use it as feedback.
 
So, I setup the AUX_PWM 2 output mode as a feedback source, but when I do, I cannot find it back in any of the other AUX_PWM functions closed loop->feedback setup or axis source, only the usual suspects as RPM, MAP, etc. So, only the conventional control sensors…
 
This is to control my radiator fan, on coolant temp in and out, airco HP pressure, and water intercooler radiator temp.
 
Where could I find the AUX_PWM1-2 output when it’s used as a feedback output?
Reply 0 0
littleozfella
Hi
          So the PWM1 Feedback becomes the Source channel for the closed loop control for the second table. So instead of using PWM2 to control say fuel pressure you are, using the PWM2 to control the parameter generated by the first table as the channel to be controlled by closed loop. Not to be used on an axis of another table. so you can set say Oil temp and water temp on the axis of PWM 1, I am not sure if you can then use say your aircon press and intercooler temp on another PWM but I don't think you will be able to combine them?? you could wire 2 outputs to one fan I suppose, may pay to have a diode to prevent feedback?? Hmm just looking on latest SQ codes there are 5 PWM outputs BUT only 1 and 2 can be used as sources, the code update doesn't include the later inclusion of PWM 3 to 5
[178729%2F9210781%2Fmceclip0]
 
    There is one Fan output that is designed to be used for water injection (Layover from T6 Ford Escort GrpA/WRC days). (Fan 2)
 
Cheers
Reply 0 0
MarcoV6T
Thanks littleozfella !
 
I should have thought about it that those virtual feedback outputs would only be available for PWM1 or 2, but not for PWM3 to 5.
 
My idea was to use both virtual feedback outputs, from PWM1-2, and use them as an axis source (rather than a feedback source).
Thus, setting the X-Axis source as ECT, the Y-Axis as SPT1(radiator out temp) for the PWM1 feedback output.
And, setting the X-Axis source as SPP1 (AC HP), the Y-Axis as AAT (intercooler water temp, I use ACT for fueling corrections) for the PWM2 feedback output.
Then, using the feedback from the PWM1 output as the X-Axis source and the feedback from the PWM2 output as the Y-Axis for PWM3, so I can blend all the sources into one PWM output.
 
But one cannot use the virtual feedbacks as an axis source anyway, and using it as feedback for the PID loop will not work in my case, because I’m using unrelated channels I need to blend into each other, not to control each other.
 
One could “hard wire” two PWM outputs together no problem, as they are open collector outputs, but the two PWM outputs will overlap at some point, and would give an erratic outcome.
 
The water injection fan output function has only an on/off output, no PWM, so I cannot use it in my application.
 
Cheers
Reply 0 0
MarcoV6T
“But one cannot use the virtual feedbacks as an axis source anyway, and using it as feedback for the PID loop will not work in my case, because I’m using unrelated channels I need to blend into each other, not to control each other.”
 
Well, I could do it, setting up two PWM channels and feeding them back into two analog inputs, but then I lose two PWM outputs and two analog inputs.
Reply 0 0
littleozfella
Do you have any other devices on the car, ICD, or other??
Reply 0 0
Reply