Hi All,
I have run into a UD CAN issue that I cannot seem to figure out. Cyl2_t_inj does not seem to be transmitting correctly from the SQ6 to the L2 logger. The interesting thing is that everything from CAN ID 200 to 210 is transmitting fine and even within ID 208 the other frames are transmitting the correct data. Below is a sample of the table I've used to configure the data. Viewing the live data in CALTOOL suggest that inj2 is working nominally.
 
I have not yet hooked up a CAN sniffer, but wanted to see if anyone has some suggestions.
 
Is there a list of the enumerations for the fuel self learning states? Seems to range from 0 to 11. Or is it a bit field channel?
 
CAN IDRate(Hz)1234
0x20050IGN_Angle Cyl 1_ECU (49836)IGN_Angle Cyl 2_ECU (49837)IGN_Angle Cyl 3_ECU (49838)IGN_Angle Cyl 4_ECU (49839)
0x20850IGN_Angle Cyl 5_ECU (49840)IGN_Angle Cyl 6_ECU (49841) cyl1_t_inj (49675) cyl2_t_inj (49676)
0x21050 cyl3_t_inj (49677) cyl4_t_inj (49678) cyl5_t_inj (49679) cyl6_t_inj (49680)
Reply 0 0
Alex
The Inj 2 issues was due to incorrect scaling in ToolBox. It defaulted to "s" while all the other injector times defaulted to "ms".

Still hoping someone has some info on the fuel self learning states. Seems to range from 0 to 11 in Toolbox. Is it a bit field channel?
Reply 0 0