shazen
I received a used IPS32 mark 1 and connected it to my windows PC running 
Pi Toolset Version 5.3 (Build 2620 - Update 7)
Pi Data Access Version 8.2 (Build 756)
I had a successful connection and had 99% during "TEST CONNECTION".
I was able to "Read from Active Device" to get the name of the Setup which shows up in the "Existing Setups" box.

When I double clicked the setup, it was not able to read the unit. Attached is an image of the dialog box that popped up.
Is there something I've missed? How can I get "in" to work on the setup?

thank you, Steve
issueImage.png 
Quote 0 0
littleozfella
Hi.. I would need somebody at Cosworth to confirm this but I think you have too late version of Toolset to connect with this version of code.. OR you are trying to connect to a Hyluss not an IPS.  They look the same but are different units.  Can you send a photo of the ID tag?
Cheers..
Quote 0 0
shazen
Hi littlozfella,
Thank you for the reply. I got your other email too. Here is an image of the ID tag. If you have a newer or older version of Pi Toolset that you think might work, please email or dropbox it to me.. much thanks. steve (dot) hazen (at) outlook (dot) com

IMG_20181231_075815.jpg 
Quote 0 0
littleozfella
send you a link to 6.1 toolset. I don't know what a TLA is, would need somebody from Cosworth to answer that.
Quote 0 0
shazen
Thank you very much. With that 6.1, it worked fine.
Quote 0 0