Hi Support,

I'm trying to connect to a customer's Omega D2 display using Toolset 6.1 to clear the logging memory. However, the device is not appearing when I go to add a new device.

I have configured my IPv4 address to 172.16.255.13 with subnet mask 255.255.0.0, and ensured Toolbox is allowed to communicate through Windows Firewall. I have also made sure Toolset is using the Ethernet network adapter.

Do you have any suggestions for me to try?

Thanks in advance
Reply 0 0
G&G Motorsport
Try,
172.16.255.129.
255.255.0.0
Reply 0 0
PaddonRallysport
Thanks for your reply.
172.16.255.129 did not work for me. Are there any other combinations I can try?
Reply 0 0
littleozfella
PM'd
Reply 0 0