Wedders
Hi,
Can you confirm the correct usage and funcationality of the COND function in Toolbox.
For example the following (I think),

cond([Channel],0.5,0.75,0 )


Should return a value of 1 when; 
The value of Channel is non-zero for the preceding 0.5 seconds and post 0.75 seconds. 

However, in practice the resultant channel only goes TRUE for a single sample after the condition evaluates true. 
My interpretation is that the resultant would hold true whilst the source channel continued to evaluate True.

This function could be very useful in creating an 'evaluation window' with which I can then scrutinize other variables. 
Any feedback appreciated. Wedders.
Quote 0 0
Wedders
Ah.. highly disappointing....  the manual implys this function only works in the world-of-pain that is soft events.  but cant currently get it to work within that framework.
Quote 0 0
littleozfella
you have an email [biggrin]
Quote 0 0
Wedders
Cheers Lil' Fella 😉    Who knew you'd be here 😉   Was getting a bit stressed end of day, yesterday.

For the Cosworth team; The function is working well in Soft Events but I can see how to use that event in any subsequent maths/channel evaluation.  Can you confirm if that is possible.
Wedders.
Quote 0 0