ValPopescu
The NTK Lambda senor has  12V and GND terminals for pre-heating.. I have no idea how much current goes through the pre-heater but if less than 1A I'd like to use Sq6M 12V and Digital GND capable of 1A continue current. 
Will it work?
Reply 0 0
ValPopescu
Correction: PWM is used for the heater GND so the question applies only to the 12V pin
Reply 0 0
RobF

No you should not power the 12v from the sensor 12v pin. Use the same feed that powers the ECU as long as the circuit can deal with the current. Lambda can peak upto around 7A when heating. 

You can use the AN ground pin for the signal ground

The other side of the heater goes to PWM like you’ve already mentioned.

Reply 0 0
ValPopescu
I actually I designed a PCB to deal with all connections and spec-ed the current for all power traces. Easy to add 7A. 
Thanks
Reply 0 0