Alex
Hi All, 
Recently ran into a new problem where I cannot enter patching with a SQ6. I can however send datasets to the ECU and it will accept the changes and restart. Upon trying to enter patching I get the dialog box that as if I want to send current dataset or create based of active device. After that is the error for not entering patching with the option to view in the journal. I then restarted the PC, so no other software was open, same issue. 
 
Open to ideas, tests or suggestions. 
Reply 0 0
Alex
The issue came about from INPUT FUNCTIONS>LAP BEACON>SPLIT TIMES>Number of Splits having a value of 0. This then caused issues with Split Distances and Reference Lap Split Times. They ended up displaying <invalid value>, but that was hidden by the fact this splits were set to 0. Setting the splits to a integer and populating the subsequent tables allowed me to patch. I will try again, in my spare time, to enter a split of 0 to see if the problem persists.
Reply 0 0
littleozfella
Go to View and check Show Validity this should show up errors (red) and undesirable values (brown/orange)  Red you won't be able to send the dataset, brown/orange you should correct the values.   BUT I think I had this issue and it does not show up.  
 
Cheers
Reply 0 0
Alex
Correct, It does show up as grey. I did not notice it at the time.
 
When I have a value greater than 0 in Number of splits and valid values in Split Distances and Reference Lap Split Times, everything works as normal. As soon as I change number of splits to 0 the grey indicators show up(invalid). I do find this odd since the cell minimum is 0....
 
[178729%2F8250564%2Fmceclip0]
Reply 0 0
littleozfella
Yeah I think the naming isn't so straight forward. 0 "split" would mean the track had no ending. I guess the min value should be 1. Split 1 would be the total track length.   I only used this once and that was about 4 or so years ago so I can't remember.  
 
Cheers.
Reply 0 0