Alex
Hi,
I noticed that the display brightness was not changing with ambient lighting. From bright sun light to finger over the sensor, no change. Looking at the LDR voltage on the live data, it appears flat-lined at 0V regardless of lighting conditions. Is there another way to test this input, are there any known failures of this sensor? Suggestions and/or advice is welcomed.
 
-Alex
Reply 0 0
RobF
Hi,
I noticed that the display brightness was not changing with ambient lighting. From bright sun light to finger over the sensor, no change. Looking at the LDR voltage on the live data, it appears flat-lined at 0V regardless of lighting conditions. Is there another way to test this input, are there any known failures of this sensor? Suggestions and/or advice is welcomed.
 
-Alex
Hi Alex, can you share what software version and variant you are using please?
Is it a normal Cosworth ICD, or is it a Porsche/Renault ICD?
Thanks
Reply 0 0
Alex
Hi Rob,
It is a normal ICD, Metadata 12.0, Variant 8.3. Software is Toolset, Version 10.3(Build 4908 - Update 9).
Reply 0 0
Alex
Hi Rob,
Just updated to Metadata 15.0, Variant 8.3. The LDR is functioning now. ¯\_(ツ)_/¯
 
Let me know if you want me to go back to 12.0 to do any debugging. However, I am good to go for now.
 
-Alex
Reply 0 0
RobF
Hi Rob,
Just updated to Metadata 15.0, Variant 8.3. The LDR is functioning now. ¯\_(ツ)_/¯
 
Let me know if you want me to go back to 12.0 to do any debugging. However, I am good to go for now.
 
-Alex
Glad you are sorted, from memory there was a bug in one release, and as you have seen was fixed in later release. Glad you're now sorted.
 
Let me know if you need anything else.
Reply 0 0
Reply