hoytf
We are running multiple IPS32 units in one vehicle and multiple IPS32-MK2 units in another vehicle.  Both vehicles control the units via canbus.  In each vehicle, all of the units are interfaced to a single 1Mbit canbus.  And yes, we have the proper resistors terminating the canbus.

We are seeing simultaneous crashes of all units in the vehicles.  In other words, all of the IPS32 units in a vehicle crash at the exact same time for unknown reasons.  The units then reboot and continue working properly until the next crash.  Single units never crash apart from the other units.  The only crashes occur when all of the units crash together.

The time between crashes is significant.  The units often work for days without crashing.  The canbus is running around 20% utilization and our canbus monitor has not detected malformed packets or other errors.  That said, we have not been able to trap the canbus communications during a crash due to the length of time between crashes.

Has anyone else experienced IPS32 units crashing due to some type of canbus event?

Has anyone had failures running IPS32 units at 1Mbit?  (We are thinking about slowing the canbus bitrate to 250kbit.)  

Thank you.

Hoyt
Reply 0 0
littleozfella
Hi Hoyt.  99.99% of motorsport use 1mbit CAN.  When you say Crash, do you mean the units power down or the busses "lock up/crash"??  Can you post the wiring of your system? Only 2 units should have termination resistors, the units at each end of the bus.  Are you using shielded CAN wires??

Cheers.
Reply 0 0