Alex
Requesting technical bulletins for Ignition Idle setup, ABV control setup and Wastegate control.

My questions are thus:

  1. When setting up ignition idle control it seems like Idle Ignition Adder (Positive Error) and (Negative Error) do not impact how the car idles, regardless of the values I put in.
    • In order to trouble shoot, what numerical channels should I be looking at to make sure everything is correctly enable?
  2. Similar story for Air Bypass Valve Base Duty Cycle. Though when I change Air Bypass Valve Transfer Function, the idle is impacted.
    • What is Air Bypass Valve Transfer Function and how is it intended to be used?
    • What is the proper work flow for setting up ABV?
    • The output is actually working as tested using and AUX PWM channel.
    • Closed throttle is true during idling
  3. For wastegate control,
    • What is Wastegate Duty Transfer Function and what is its intended use?
    • If closed loop is disable is WG Duty driven only by Base Wastegate Control Duty Map (First Gear) 1? Provided the car is in 1st gear.

Thank you,
Alex
Reply 0 0
littleozfella
Hi Alex,
            Use Quick View (Alt-Q) and on the right will be the parameters you need to view when you have an Idle Control related parameter open. The channel fbwClosedLoopIdleEnable must be True.  If this is not enabled then the setting for closed throttle must be correct, the channel is closedThrottle Closed throttle is setup in the Throttle setup area.This isn't in the quick view menu so I have sent you an Idle worksheet template.  Also if you have a turbo engine there are settings in Anit-Lag that can prevent the Idle strategy from being enabled. Basically if ALS in on, the Ign adder can be prevented. IF you are not in CAL1 then your system will have ALS on, beware ALS isn't on.
 Air bypass valve is idle valve, Under Idle Control you have Closed Loop Idle View Select set to Show FBW so the ECU is thinking it has a FBW throttle for idle control. Set to Show ABV.  This will then show the bypass valve functions.

   Transfer function in all controls is so you can Characterise your valve, ie the WG valve may not flow any air until 20% duty and flow no more air after 80% so you would set 0 to 20 and 100 to 80 and interpolate. In this case when the table has 10 in the values the valve will be flowing air to the WG, Also not all (most) wastegate valves are not linear in their flow, you can  Characterise this linearization also.
Reply 0 0