Issue 1:
The initial issue I faced was that the device did not appear to be logging any data. There were no data files present when trying to download after a session. I don't believe this to be a configuration issue within the setup file as these are all locked by Porsche and not able to be modified.
 
Troubleshooting Issue 1:
Toolset versions being used: Version 7.0 (Build 3438-Update 2)
Made sure that the active device was in fact the ICD #4081
I ruled out the Toolset version and my laptop being the issue as I did not have any issues with other Gen 2 Cup cars.
 
I updated the device firmware to the latest code package available on the Porsche Motorsport Service Information database.
Firmware version: ICD-01D-032953-13.1_2019-04-15_Update-2.code
Firmware update was successful after disabling Windows firewall and AVG antivirus
 
Issue 2: 
After updating the firmware I now have to reupload the ICD setup file but am unable to do so. The upload progresses for a while and then fails at "Updating capabilities token.."
 
Troubleshooting Issue 2:
I have followed the Porsche 991 GT3 Cup Gen 2 Cosworth Firmware Update Guide
Both the ICD device and setup file have matching variants.
I have made sure AVG antivirus and Windows firewalls are disabled.
I have also tried with several different laptops but all have the same results.
 
ICD setup file im trying to upload is: ICD_CUP17_ABSM4_0501_S_V12
However I also tried all the setup file versions with matching variants on the Porsche database and still had the same issue
 
I am connecting to the car via the ethernet cable and have used the "Test Connection" function within Toolset to verify communication is good.
 
Are there any hidden settings I should be checking or disabling that could be causing this issue?
 
Would the best course of action be to send the device back to Cosworth to be looked at?
Reply 0 0
RobF
dk15 wrote:
Issue 1:
The initial issue I faced was that the device did not appear to be logging any data. There were no data files present when trying to download after a session. I don't believe this to be a configuration issue within the setup file as these are all locked by Porsche and not able to be modified.
 
Troubleshooting Issue 1:
Toolset versions being used: Version 7.0 (Build 3438-Update 2)
Made sure that the active device was in fact the ICD #4081
I ruled out the Toolset version and my laptop being the issue as I did not have any issues with other Gen 2 Cup cars.
 
I updated the device firmware to the latest code package available on the Porsche Motorsport Service Information database.
Firmware version: ICD-01D-032953-13.1_2019-04-15_Update-2.code
Firmware update was successful after disabling Windows firewall and AVG antivirus
 
Issue 2: 
After updating the firmware I now have to reupload the ICD setup file but am unable to do so. The upload progresses for a while and then fails at "Updating capabilities token.."
 
Troubleshooting Issue 2:
I have followed the Porsche 991 GT3 Cup Gen 2 Cosworth Firmware Update Guide
Both the ICD device and setup file have matching variants.
I have made sure AVG antivirus and Windows firewalls are disabled.
I have also tried with several different laptops but all have the same results.
 
ICD setup file im trying to upload is: ICD_CUP17_ABSM4_0501_S_V12
However I also tried all the setup file versions with matching variants on the Porsche database and still had the same issue
 
I am connecting to the car via the ethernet cable and have used the "Test Connection" function within Toolset to verify communication is good.
 
Are there any hidden settings I should be checking or disabling that could be causing this issue?
 
Would the best course of action be to send the device back to Cosworth to be looked at?



When you load new firmware to an ICD, the token (which determines the level) is removed, so you’ll need to reload the token, then send the setup. 

By the sounds you have a setup and token mismatch which is why you can’t send. 

If you contact Cosworth with your ICD serial number, the token variant and which one you need (no doubt P-CUP but there are quite a few variants if you have an endurance setup for example) they can resupply it. 

Reply 0 0
dk15
Thanks for the suggestion RobF. Unfortunately this did not resolve the issue. The setup upload still fails at "updating capabilities token" even after reloading the token file from Cosworth. I am positive I have disabled any antivirus/windows firewall settings so I am unsure what could be the issue. Would you have any other suggestions?
Reply 0 0
Reply