leisurehound
Hi:

I'm investigating installing an ICD into my car and am working with a dealer but there are still some unanswered questions that I'm hoping someone here can help with before I make the decision to purchase.

Specifically:
- I see that the pin outs state 2 ethernet connections (4 pairs) one for PC one connecting to the internal hub.  Further in the spec sheet it says both are connected to the internal hub.  I have a vehicle router and a co-processor on the network and would like to simply add the ICD as a node.  Will download work when attaching Toolset to the vehicle network via joining the vehicle's router wifi?  What port is Toolset scanning for the ICD on such that I can ensure no other devices on the network are responding on that port?  Or can I set Toolset to look for a static IP?

-Which switch inputs are used to paginate through the display? Or is it configured in Toolset?  Is there a way to create a ICD configuration in Toolset before connecting the device?

-Are the high side drivers limited to 0.7A like the Omega L2?  Is there a overage allowance/safety factor?  I need 1A continuous so not sure if I need a relay.

-Can MATHs computed on device be exported on any CAN interface?

-Does the ICD have an upper limit of number of channels to record like the Omega L2 or is it simply bound by the bytes/sec upper bound?

Thanks in advance.
Reply 0 0
littleozfella
Hi, I can answer some of your questions.
 1. We have used an external Wi-fi router to connect to Cosworth devices via the comms ethernet so I guess this should be ok. Cosworth devices have a defined IP address so your computer will look for a specific ID.
2. You can use any digital input to change pages, or you can use a CAN input setup to be a Button in the CAN receive message. CAN is very configurable, but you need to use the latest versions of code. Yes of course you can make configuration before connecting to the device, you must beware that logging bandwidth may not be defined until you connect to the device, ie you may be given a message you are over the bandwidth but otherwise any errors will be shown in the column on the right side of the screen. Warnings are allowable, errors are not. Be sure you are using the same metafile version as your device when making the setup, these can be converted but it is better to start with the correct version. For instance, no point in making an Ultra setup if you have a plus version ICD.
3. If the device requires constantly more AMPS than the defined output current then you would need a relay, you can test it but allow in your looms.
4. Maths can be used in CAN, the CAN in ICD/IPS is totally configurable. Be careful with maths, depends on your option you may have a limited number of maths channels. Remember in many cases you can use logic instead of maths, both able to be exported over CAN.
5. Logging depends on your option, I think you will run out of bandwidth before number of channels.
Reply 0 0
leisurehound
Thanks for your reply Mick.  Follow on questions below:

Hi, I can answer some of your questions.
 1. We have used an external Wi-fi router to connect to Cosworth devices via the comms ethernet so I guess this should be ok. Cosworth devices have a defined IP address so your computer will look for a specific ID.


Do you know what that IP address so I can set up the router span subnets?  Are all ICD set with the same IP (makes sense, since there won't be more than one a car)


2. You can use any digital input to change pages, or you can use a CAN input setup to be a Button in the CAN receive message. CAN is very configurable, but you need to use the latest versions of code. Yes of course you can make configuration before connecting to the device, you must beware that logging bandwidth may not be defined until you connect to the device, ie you may be given a message you are over the bandwidth but otherwise any errors will be shown in the column on the right side of the screen. Warnings are allowable, errors are not. Be sure you are using the same metafile version as your device when making the setup, these can be converted but it is better to start with the correct version. For instance, no point in making an Ultra setup if you have a plus version ICD.


Thanks.  My experience was plugging in and editing a config on other cars, but was at a bit of a loss of how to start from scratch with no device yet to plug into.  I will look closer again at this.  Thanks for the tips on starting with the right metafile for the version I'm installing.


3. If the device requires constantly more AMPS than the defined output current then you would need a relay, you can test it but allow in your looms.


The reason I ask is that the current limit is listed in the Omega L2 pin definition 0.7A (page 5) (https://d28lcup14p4e72.cloudfront.net/178729/3763906/L2-29L-071648.pdf) but not on the similar ICD pin definition (page 4) (https://d28lcup14p4e72.cloudfront.net/178729/3763891/ICD-29D-032953-P.pdf)


4. Maths can be used in CAN, the CAN in ICD/IPS is totally configurable. Be careful with maths, depends on your option you may have a limited number of maths channels. Remember in many cases you can use logic instead of maths, both able to be exported over CAN.
5. Logging depends on your option, I think you will run out of bandwidth before number of channels.


Again the L2 product matrix lists both bandwidth and max number of channels for each Plus/Pro/Ultra config (https://www.cosworth.com/wp-content/uploads/2017/11/clu_product_overview_v1.3POREDUCE.pdf) but the ICD matrix only lists bandwidth for each config (https://www.cosworth.com/wp-content/uploads/2017/11/2019-01-09-ICD-Brochure-A4.pdf)  I'm well below the Omega L2 channel cap, but not sure if the ICD has a lower channel limit or its simply bandwidth limited.

Thanks again.
Reply 0 0
Reply