Thanks for your reply Mick. Follow on questions below:
Hi, I can answer some of your questions.
1. We have used an external Wi-fi router to connect to Cosworth devices via the comms ethernet so I guess this should be ok. Cosworth devices have a defined IP address so your computer will look for a specific ID.
Do you know what that IP address so I can set up the router span subnets? Are all ICD set with the same IP (makes sense, since there won't be more than one a car)
2. You can use any digital input to change pages, or you can use a CAN input setup to be a Button in the CAN receive message. CAN is very configurable, but you need to use the latest versions of code. Yes of course you can make configuration before connecting to the device, you must beware that logging bandwidth may not be defined until you connect to the device, ie you may be given a message you are over the bandwidth but otherwise any errors will be shown in the column on the right side of the screen. Warnings are allowable, errors are not. Be sure you are using the same metafile version as your device when making the setup, these can be converted but it is better to start with the correct version. For instance, no point in making an Ultra setup if you have a plus version ICD.
Thanks. My experience was plugging in and editing a config on other cars, but was at a bit of a loss of how to start from scratch with no device yet to plug into. I will look closer again at this. Thanks for the tips on starting with the right metafile for the version I'm installing.
3. If the device requires constantly more AMPS than the defined output current then you would need a relay, you can test it but allow in your looms.
The reason I ask is that the current limit is listed in the Omega L2 pin definition 0.7A (page 5) (https://d28lcup14p4e72.cloudfront.net/178729/3763906/L2-29L-071648.pdf) but not on the similar ICD pin definition (page 4) (https://d28lcup14p4e72.cloudfront.net/178729/3763891/ICD-29D-032953-P.pdf)
4. Maths can be used in CAN, the CAN in ICD/IPS is totally configurable. Be careful with maths, depends on your option you may have a limited number of maths channels. Remember in many cases you can use logic instead of maths, both able to be exported over CAN.
5. Logging depends on your option, I think you will run out of bandwidth before number of channels.
Again the L2 product matrix lists both bandwidth and max number of channels for each Plus/Pro/Ultra config (https://www.cosworth.com/wp-content/uploads/2017/11/clu_product_overview_v1.3POREDUCE.pdf) but the ICD matrix only lists bandwidth for each config (https://www.cosworth.com/wp-content/uploads/2017/11/2019-01-09-ICD-Brochure-A4.pdf) I'm well below the Omega L2 channel cap, but not sure if the ICD has a lower channel limit or its simply bandwidth limited.
Thanks again.