rsantos
Hi,
 
We're working on a solution for our professional racing simulator and we would like to use our actual steering wheels from the car in the sim. Our simulator PCs have CAN cards installed on them, so we have a CAN stream set from our simulation software through a 9-pin D-sub connector.
 
Our wheels have CDU dashes and Cosworth CAN Switch Boards on them and we would like to be able to use them on the simulator. Given that our sim data is already logged in the computer by our Sim software, we don't need a logging unit in the sim for any reason other than controlling the dash. Thus, we would like to know if there is a way that we can control the CDU without having to resort to an expensive logging unit or ECU?
 
I know CDU uses Ethernet communication to receive data. Would having a CAN-Ethernet or CAN-Ethercat interface work with that?
 
Thanks in advance.
Reply 0 0
Andrew
Hello,
 
Technically you can create your own UDP stream to drive channel data to the CDU, in practice there are other software conciderations need to be accounted for in your cost comparisons. You would need to develop PC software that converts the channel data from the SIM interface and sends it in a Cosworth data format over ethernet to the CDU.
 
I have not estimated this effort before, but my hunch says that the net benefit would be to buy our cheapest logger (Badenia 2) and connect that via your CAN card. This gives you the best workflow and best solution long term as you will gain much more than just a logger in the system. 
Reply 0 0
rsantos
Hello,
 
Technically you can create your own UDP stream to drive channel data to the CDU, in practice there are other software conciderations need to be accounted for in your cost comparisons. You would need to develop PC software that converts the channel data from the SIM interface and sends it in a Cosworth data format over ethernet to the CDU.
 
I have not estimated this effort before, but my hunch says that the net benefit would be to buy our cheapest logger (Badenia 2) and connect that via your CAN card. This gives you the best workflow and best solution long term as you will gain much more than just a logger in the system. 
Hi Andrew,
 
Thanks for your reply. Is there any documentation that would help me to understand how to create a stream in Cosworth Data Format? We have a PiDAE file creator license, that we use to convert data created in the sim to .pds files so that we can compare it with track data, does that help us at all with creating UDP packets in Cosworth data format?
 
Also, if that solution is possible, how would I proceed to send Toolset setups to the CDU alone, so that we would have our custom dash pages?

Thanks,

Rodrigo
Reply 0 0
Andrew
Hi Rodigo, 
 
I will find out and let you know. We will have internal documentation, but nothing customer facing as most customers use the Display devices with our compute modules. 
Reply 0 0
rsantos
Hi Rodigo,
 
I will find out and let you know. We will have internal documentation, but nothing customer facing as most customers use the Display devices with our compute modules.
Thank you Andrew, that will be very helpful, and greatly appreciated!
Reply 0 0
rsantos
Hi Andrew, do you have any updates on that front? Thank you.
Reply 0 0
Andrew
Hi Rodrigo,
 
Sadly no progress as yet, our main system architect is on his summer break, soon as I see him I will ask.
Reply 0 0
Reply