SpecialK
Hey there, I'm completely new to the Cosworth platform and I'm slowly working my way around learning about it.

Build plans are a SQ6, IPS32 and a dash. Was going to go with the ICD but I like the size and looks of the CDU 4.3 way more. I cannot find anyone or any information on how setting up the CDU would go.

Is there anyone here who is using one who would be interested in sharing some tips and tricks?

Can I play with the software for the dash config without having a dash connected up to the software?
If yes, can you please explain what is needed and how its done?

Thanks In Advance
Reply 0 0
RobF

You can configure / play with a setup for the dash in Toolset without it connected. 

It is worth pointing out however the CDU is different to the ICD in the sense it’s a ‘dumb display’ . ICD is a combined dash/logger which can be used completely on its own, the CDU is an Ethernet display that takes all its info from a compatible Cosworth ECU, logger, or PDU (new ones only).

So if you went for SQ6 + IPS + CDU, the CDU wouldn’t work as the other products aren’t compatible with it.

Youd need either a MQ12DI ECU, L2/CLU Dedicated Logger, New ‘Badenia’ Logger or new ‘Centaurus’ PDU not IPS. Doesn’t have to be all of them, just one of them. 

Base L2 + CDU would work out similar cost to a high spec ICD so could be worth looking at that option. 

Reply 0 0
SpecialK
This is what I was afraid of. Can it work with atleast a MQ12 or only the MQ12DI?

If not I'll have to stick with the original ICD idea. Can you explain how do I go about playing with the dash setup in Toolset? I cannot seem to figure out how its done. Unless its in settings but I do not have the setup file to load onto software to play with the displays.

Thanks for the quick response
Reply 0 0
littleozfella
Top right hand corner, of Setups Screen  Click on Read from device and save the file. If you don't have the device connected first you need to add the device Very first tab Devices, Click on the Plus sign +  and add the device, then click on the tick to activate the device.   Will not work with MQ12 only devices with ether comms.

cheers.
Reply 1 0
SpecialK
Top right hand corner, of Setups Screen  Click on Read from device and save the file. If you don't have the device connected first you need to add the device Very first tab Devices, Click on the Plus sign +  and add the device, then click on the tick to activate the device.   Will not work with MQ12 only devices with ether comms.

cheers.


Ahh So pretty much will not allow me to play with the config without a device connected. Understood. Thought I can play with screen layouts etc offline without a device connected.
Reply 0 0
littleozfella
You can but you need to get a base setup file first, if you have a unit connect and save the setup file. If not @RobF may have something laying about.

cheers
Reply 1 0
SpecialK
Thanks @littleozfella . RobF you mind sharing a setup file for the ICD digital dash for me to play around with display layouts in Pi Toolset? 

Can also throw in a IPS32 file as well if its not an issue. Would be good to get familiar with them in the software before I do the install.
Reply 0 0
littleozfella
I think you mean a CDU file???
Reply 0 0
SpecialK
I think you mean a CDU file???


@RobF stated the CDU displays were designed to use the newer Cosworth devices which would act as the master to run the CDU displays. Since I dont have plans on using any of the devices he stated are needed for the CDU, I would have to go with the ICD display instead. Hence why I asked for the ICD file. Also I think the IPS also uses Toolset to configure the software so I'm assuming the IPS also needs a file to be able to play with the setup functions of the IPS
Reply 0 0
Reply